APPROX.
ROOM SIZE
|
NUMBER AND TYPES OF LAMPS
RECOMMENDED |
| . |
Minimum |
Maximum |
|
|
UP TO
10' x 12'
(120 sq.ft.)
|
2-40W/34W or 32W |
4-40W/34W or 32W |
| 2-U40W/34W or 32W |
4-U40W/34W or 32W |
| 4-20W |
8-20W |
|
|
UP TO
12' x 18'
(216 sq.ft.)
|
4-40W/34W or 32W |
8-40W/34W or 32W |
| 4-U40W/34W or 32W |
8-U40W/34W or 32W |
| 8-20W |
|
|
|
NOTE:
Space fixtures 6' to 8' apart to create uniform illumination.
Recommendations are for an 8' ceiling. |
|
In addition to
room length and width, other factors that should be considered
are ceiling height; color of walls, ceiling and floors; other
light sources in the area; and the amount of natural light entering
the space.
For optimum appearance
and efficiency, circline fixtures and 12 to 20 watt fixtures
are best suited for bedrooms, laundry rooms, halls, closets and
other areas where light levels are less critical.
|
| SYMPTOM |
. |
CORRECTIVE ACTION |
|
. |
|
LAMP(S)
WILL NOT OPERATE: |
1. |
Be sure lamp is properly
seated in socket. |
| 2. |
Replace lamp. |
| 3. |
Reseat or change starter
(preheat only). |
| 4. |
Check wiring connections. |
| 5. |
Test ballast. |
|
. |
|
SLOW
OR ERRATIC STARTING |
1. |
Be sure lamp is properly
seated in socket. |
| 2. |
Check ballast label for
correct lamp. |
| 3. |
Check wiring connections. |
| 4. |
Check for low supply
voltage. |
| 5. |
Check ground (Fixture
must be properly grounded for reliable starting.) |
| 6. |
Test ballast. |
|
. |
|
BLINKING,
SNAKING OR FLICKERING |
1. |
Turn fixture on and off
several times at one-half hour intervals. |
| 2. |
Check ambient temperature
and change to ballast rated for conditions if below 50°F * (Check for fans or air conditioners
blowing across lamps). |
| 3. |
Check wiring connections. |
| 4. |
Check supply voltage. |
|
. |
|
REDUCED
LIGHT OUTPUT |
1. |
Check for ambient temperature significantly
above or below 70°F. |
| 2. |
Check for fans or air conditioners blowing
across lamps. |
| 3. |
Check wiring connections. |
| 4. |
Test ballast. |
|
. |
|
RADIO
INTERFERENCE |
1. |
Move electronics at least 10' from lamps. |
| 2. |
install Radio Interference Filter. |
| 3. |
Improve equipment grounding or install
shielded and grounded radio antenna. |
|
. |
|
REPEATED
CYCLING (ON/OFF) |
1. |
Check ballast label for correct lamp
cycling. |
| 2. |
Check wiring connections. |
| 3. |
Check voltage. supply. |
| 4. |
Check for higher ambient temperatures,
ventilate or suspend fixture. |
| 5. |
Test ballast. |